Sloan Electronic – Concealed Dual “Touch Flush” System
- 42070M – Sloan Electronic Dual “Touch Flush” System (Mains Pressure)
- Unit comes with 2 x Power Packs and 2 meters of lead, 25mm stopcock, flush pipe nut, and vacuum breaker
- 42071L – Sloan Electronic Dual “Touch Flush” System (Tank Fed Pressure)
- Unit comes with 2 x Power Packs and 2 meters of lead, 40mm stopcock, flush pipe nut, and vacuum breaker
42070M and 42071L are the concealed electronic dual “Touch Flush” system which provides clean look and helps prevent tampering/vandalism. Suitable for mains pressure or tank fed pressure installation. The concealed dual flush system also available as an electronic “Touch Free” sensor or a hydraulic operated system. Sloan flushometers are also available in a different aesthetic as exposed models. Most water closets (toilet pans) and urinals can be combined with any Sloan Flushometer.
Features and Benefits
- Concealed system can be installed behind the button panel or in the ceiling space
- Provides clean look and helps prevent tampering/vandalism
- Suitable for mains or tank pressure installation
- Electronic “Touch Flush” operation
- The Dual Flush Touch Pad* has sensor built into it – easy operation with a light touch on the wall plate (*available for purchase separately)
- Interchangeable flushing volumes
- Standard: 6/3 L
- Optional: 4.5/2.2 L
- Delivers a complete flush and refill, immediately ready for repeat operation
- Flush under pressure, more efficiently cleanses the fixture
- Compact and easy to install
- Can be paired with two different look panels as optional accessories available for purchase
- Flush valves retrofit/changeover to suit old models (subject to verification – please contact us)
- WaterMark and ADA approved
- Most water closets (toilet pans) and urinals can be combined with any Sloan Flushometer
Space Requirements
- Minimum wall cavity (D): 140mm
- Minimum width of assembly (W): 270mm
- Minimum height of assembly (H): 200mm
Technical Plumbing Requirements – Mains Pressure
- Minimum water supply pressure: 150kPa
- Maximum water supply pressure: 600kPa
- Minimum flow rate at the valve: 1L/sec
- Stop valve inlet: 25mm BSP
- Flush valve outlet: 40mm BSP
Technical Plumbing Requirements – Tank Fed Pressure
- Minimum water supply pressure: 40kPa
- Maximum water supply pressure: 300kPa
- Minimum flow rate at the valve: 1L/sec
- Stop valve inlet: 40mm BSP
- Flush valve outlet: 40mm BSP
Applications
This product is perfect for Commercial Office Buildings, Schools, Hospitals, Shopping Centres, Public Restrooms and other high-traffic restroom applications.
- Installation should comply to AS3500 - National Australian Plumbing Code and any other local and applicable codes
- Image is for illustration purposes only
- Due to continuous product improvement, changes to specifications may be made without prior notice