Pre-Plumbed Horne Thermostatic Mixing Valve (TMV) with In-line Thermal Disinfection Unit (ILTDU)
42511
42511 – Pre-Plumbed Horne In-line Thermal Disinfection Unit (ILTDU) & Horne H1502 Thermostatic Mixing Valve (TMV) in a recessed box configuration with lockable hinged stainless steel door – pipes at both ends.
The Horne In-Line Thermal Disinfection Unit (ILTDU), 94339, facilitates periodic high temperature thermal disinfection using the readily available hot water supply. The thermal regime can be extended to all downstream components i.e., taps, and showers. Whereas the Horne TMV (Thermostatic Mixing Valve) H1502, which is available in brass and chrome finish, has two isolating valves, two strainers and two non-return valves. The Horne TMVs are designed for reliable temperature control in plumbing systems. Engineered for long-lasting performance, Horne 42036 and 42150 ensure consistent water temperature, meeting safety standards essential for commercial and residential applications.
Features and Benefits of 42511
- Proudly Made in Australia
- Different configurations available
- Servicing is easy and accessible from the front of the box
- All the features and benefits of Horne ILTDU
- All the features and benefits of Horne H1502 TMV
Features and Benefits of Horne ILTDU – 94697
- The disinfection mode is activated by turning the unique key (available for purchase separately)
- Enables periodic high-temperature thermal disinfection using the existing hot water supply, raising downstream components to system temperature ensuring downstream fittings are safely flushed
- Designed to combat bacterial contamination such as Legionella and Pseudomonas
- Prevents biofilm growth in “dead-leg” or low-flow pipework, improving hygiene in domestic and commercial hot water systems.
- Durable chrome-plated valve body designed for long service life
- Engineered for accurate and stable temperature control
- Horne ILTDU compact in-line design integrates easily into an existing pipework, and can also be pre-plumbed with or without a TMV
- Compatible with existing plumbing layouts and ideal for hospitals, aged care, correctional, educational, and sporting facilities
- WaterMark approved: WMK26181
Features and Benefits of Horne H1502 TMV – 42150 | 42036
- Provides mixed water at a steady temperature, independent of reasonable fluctuations in the temperature and/or pressure of the incoming hot water or cold water supply
- In the event of a cold water supply failure the hot inlet port will close, thus preventing scalding
- If the hot water supply ever fails and the flow of mixed water is cut off, the valve will shutdown the flow of cold water preventing cold shock
- Maintain mixed water temperature whether the supply pressures are equal or unequal
- NSW Health approved
- WaterMark approved: WMKA1895 AS 4032.1
- Can be configured with various piping system in pre-plumbed boxes fully Australian Made
If you would like to have different piping configurations for your pre-plumbed boxes, please Contact Us
Product Specifications
- Dimensions: 370mm (W) x 520mm (H) x 75mm (D)
- Water Connection: 3/4″ BSP
Technical Information – Horne TMV
- Designed to give trouble free operation in hard water areas
- 1/2″ BSP connection
- Dry weight of the valve 1.48kg
- Equipped with isolating valves, strainers, and non-return valves
Recommended Supply Pressures and Temperatures for Horne H1502 TMV
- Inlet Temperatures
- Cold supply: Min 5°C, Max 30°C
- Hot supply: Min 60°C, Max 85°C
- Flow Rates – when producing warm water at nominal 42°C
- Min mix water flow: 2.5L/min
- Max: 48L/min
- Dynamic Inlet Pressures – Hot and Cold Water
- Min: 12kPa
- Max: 600kPa
- Static Pressures
- Max: 1000kPa
Technical Specs – Horne ILTDU
- Body: DZR brass
- Seals: Nitrile/PTFE
- Four way link mechanism: stainless steel
- Pipe Connections: compression fitting 15mm
- Measurement: 51 mm between pipe centres
- Weight: 1.0kg
- Max working pressure (static): 1000kPa
- Max temperature: 85°C
How Horne ILTDU Works
- When not in use (Passive Mode), hot and cold water flows to the mixing valve and downstream fittings uninterrupted
- The operation key transfers the mechanism into Disinfection Mode; diverting hot water at system temperature to the cold water supply pipe drop
- Simultaneously, the cold water supply is closed
- Hot water at system temperature is now able to permeate all wetted parts of the system downstream of the ILTDU until the key is turned back to the passive position
- The ILTDU is operated using a unique key, which has a large red warning notice indicating the hazard of scalding hot water
- Thermal disinfection of outlets should be conducted by an appointed Responsible Person
- During disinfection, it is not possible to remove the key from the device – ensuring the warning notice is visible throughout the process
- Only on returning the device to Passive Mode will the key be removable, an immediate removal of the key following disinfection is good practice
- A local risk assessment should be conducted to ascertain the temperature and duration required for effective thermal disinfection
- For maximum effectiveness in improving water quality and minimising the rate of contamination, thermal disinfection should be conducted in combination (but not simultaneously) with elevated velocity flushing via the drain points of any downstream thermostatic mixing valve
Suitable Applications
Ideal for hospitals, aged care, and commercial facilities requiring stringent water hygiene management
- Installation should comply to AS3500 - National Australian Plumbing Code and any other local and applicable codes
- Image is for illustration purposes only
- Due to continuous product improvement, changes to specifications may be made without prior notice