Double Check Valves
Product Code
- MF9165/F – 65mm DCV (Flanged)
- MF9180/F – 80mm DCV (Flanged)
- MF91100/F – 100mm DCV (Flanged)
- MF91100/G – 100mm DCV (Grooved)
- MF91150/F – 150mm DCV (Flanged)
- MF91150/G – 150mm DCV (Grooved)
- MF91200/F – 200mm DCV (Flanged)
Product Overview
MAGFLO™ Double Check Valves backflow preventers deliver maximum protection in ‘Medium Hazard’ backflow conditions. It prevents against reversal of flow caused by back siphonage or back pressure to the potable water. Designed with ease of access in mind and with very few spare parts needed, the modular design makes MAGFLO™ valves the easiest and quickest valve to perform your mandatory yearly testing. Available in sizes from 65mm to 200mm and in Grooved or Flanged connections.
Features and Benefits of MAGFLO™ Double Check Valves Backflow Preventers
- Size options: 65mm, 80mm, 100mm, 150mm, and 200mm
- Grooved and flanged connections (see Device Connections Table)
- Fusion bonded epoxy coated ductile iron construction
- Low head loss
- Short lay lengths suitable for retrofitting to other brands
- Vertical or horizontal installations
- Top access entry for servicing
- Entire valve can be fully serviced inline
- Noryl™ replacement check valve
- WaterMark approved: AS/NZS 2845.1 WM-040347
- Lead Free
- 12-month limited warranty
Materials
- Valve Body – Ductile Iron
- Access Cover – Ductile Iron
- Polymers – Noryl™, NSF Listed
- Elastomers – Silicone
- Springs – Stainless Steel
- Coatings – FDA Approved Fusion Epoxy
Technical Specs
- Maximum working water pressure: 1200kPa
- Maximum working water temperature: 60°C
- Hydrostatic test pressure: 2400kPa
- Lay length of 65mm Flanged device: 510mm
- Lay length of 80mm Flanged device: 510mm
- Lay length of 100mm Flanged device: 535mm
- Lay length of 100mm Grooved device: 500mm
- Lay length of 150mm Flanged device: 665mm
- Lay length of 150mm Grooved device: 620mm
- Lay length of 200mm Flanged device: 1000mm
Installation
Install device as per AS3500 and any local applicable codes and manufacturer’s instructions.
Applications
- For installation on potable water lines and fire service lines
- Protects against backflow caused by back siphonage and back pressure
- Maximum protection in Medium Hazard conditions
Double Check Valve - Dimensions and Connections
Flow Characteristics of 65mm and 80mm Double Check Valve
Flow Characteristics of 100mm Double Check Valve
Flow Characteristics of 150mm Double Check Valve
Note:
- Installation should comply to AS3500 - National Australian Plumbing Code and any other local and applicable codes
- Image is for illustration purposes only
- Due to continuous product improvement, changes to specifications may be made without prior notice