Skip to main content

Reduced Pressure Zone Device

Product Code
  • MF9265/F – 65mm RPZ (Flanged)
  • MF9280/F – 80mm RPZ (Flanged)
  • MF92100/F – 100mm RPZ (Flanged)
  • MF92100/G – 100mm RPZ (Grooved)
  • MF92150/F – 150mm RPZ (Flanged)
  • MF92150/G – 150mm RPZ (Grooved)
  • MF92200/F – 200mm RPZ (Flanged)
Product Overview

MAGFLO™ Reduced Pressure Zone Devices deliver maximum protection to the potable water supply from contaminations in ‘High Hazard’ conditions. It prevents against reversal of flow caused by back siphonage or back pressure to the potable water. Designed with ease of access in mind and with very few spare parts needed, the modular design makes MAGFLO™ Reduced Pressure Zone Devices the easiest and quickest valve to perform your mandatory yearly testing.

Features and Benefits
  • Size options: 65mm, 80mm, 100mm, 150mm, and 200mm
  • Grooved and flanged connections (see Device Connections Table)
  • Fusion bonded epoxy coated ductile iron construction
  • Low head loss
  • Short lay lengths suitable for retrofitting to other brands
  • Vertical or horizontal installations
  • Relief valve port independent of check valves
  • Top access entry for servicing
  • Entire valve can be fully serviced inline
  • Noryl™ replacement check valves
  • Fewer parts needed – save money
  • Servicing ability and commissioning is easy, simple and cost effective
  • WaterMark approved: AS/NZS 2845.1 WM-040347
  • Lead Free
  • 12-month limited warranty
Materials
  • Valve Body – Ductile Iron
  • Access Cover – Ductile Iron
  • Polymers – Noryl™, NSF Listed
  • Elastomers – Silicone
  • Springs – Stainless Steel
  • Coatings – FDA Approved Fusion Epoxy
Technical Specs
  • Maximum working water pressure: 1200kPa
  • Maximum working water temperature: 60°C
  • Hydrostatic test pressure: 2400kPa
  • Maximum relief discharge rates of 65-150mm RPZD: 76 lpm
  • Maximum relief discharge rates of 200mm RPZD: 228 lpm
  • Lay length of 65mm Flanged device: 510mm
  • Lay length of 80mm Flanged device: 510mm
  • Lay length of 100mm Flanged device: 535mm
  • Lay length of 100mm Grooved device: 500mm
  • Lay length of 150mm Flanged device: 665mm
  • Lay length of 150mm Grooved device: 620mm
  • Lay length of 200mm Flanged device: 1000mm
Installation

Install device as per AS3500 and any local applicable codes and manufacturer’s instructions. Unless otherwise specified, install device at a minimum of 300mm above adequate drain with sufficient clearance for testing and maintenance.

Applications
  • Protects against backflow caused by back siphonage and back pressure
  • For installation on potable water lines in High Hazard environments
  • Maximum protection in High Hazard conditions, i.e., Medical and Mortuary Facilities, Abattoirs, Chemical Plants, Commercial Car Washing or Laundry Facilities, Universities, or Sewage Treatment Plants and Sewage Lift Stations.
Reduced Pressure Zone Device (RPZD) - Dimensions and Connections
Flow Characteristics of 65 - 100mm Reduced Pressure Zone Devices
Flow Characteristics of 150 - 200mm Reduced Pressure Zone Devices
Note:
  • Installation should comply to AS3500 - National Australian Plumbing Code and any other local and applicable codes
  • Image is for illustration purposes only
  • Due to continuous product improvement, changes to specifications may be made without prior notice

Monday - Friday: 8:00AM - 4:30PM
5 Willsmore St, Williamstown VIC 3029
T: (03) 9399 8444 | E: sales@magspp.com.au

”For over 30 years, we have delivered premium quality plumbing innovations and nimble solution fulfilment with rapid turnaround times for global projects.”
Copyright © 2026 MAG Specialised Plumbing Products. All rights reserved.