Double Detector Check Valve
Product Code
- DDCV65/WMBP – 65mm Double Detector Check Valve with 20mm Metered By-Pass
- DDCV80/WMBP – 80mm Double Detector Check Valve with 20mm Metered By-Pass
- DDCV100/WMBP – 100mm Double Detector Check Valve with 20mm Metered By-Pass
- DDCV150/WMBP – 150mm Double Detector Check Valve with 20mm Metered By-Pass
- DDCV65/WSBP – 65mm Double Detector Check Valve with 25mm Spacer By-Pass
- DDCV80/WSBP – 80mm Double Detector Check Valve with 25mm Spacer By-Pass
- DDCV100/WSBP – 100mm Double Detector Check Valve with 25mm Spacer By-Pass
- DDCV150/WSBP – 150mm Double Detector Check Valve with 25mm Spacer By-Pass
Product Overview
MAGFLO™ Double Detector Check Valves Backflow Preventer delivers maximum protection in ‘Medium Hazard’ conditions in fire service system and prevents against reversal of flow caused by back siphonage or back pressure to the potable water, with installation of the spacer or metered by-pass assembly for detecting low flow and unauthorised water use or leaks.
Features and Benefits
- Size options: 65mm, 80mm, 100mm and 150mm
- Flanged and Grooved connections (see Device Connections Table)
- Available with 20mm metered or 25mm spacer by-pass
- Copper bends and copper olive fittings for rotable position of by-pass
- Fusion bonded epoxy coated ductile iron construction
- Short lay lengths suitable for retrofitting to other brands
- Vertical or horizontal installations
- Top access entry for servicing
- Entire valve can be fully serviced inline – lightweight short lay length modular design
- Noryl™ replacement check valve
- WaterMark approved: AS/NZS 2845.1 WM-040347
- Lead Free
- 12-month limited warranty
Materials
- Valve Body – Ductile Iron
- Access Cover – Ductile Iron
- Polymers – Noryl™, NSF Listed
- Elastomers – Silicone
- Springs – Stainless Steel
- Coatings – FDA Approved Fusion Epoxy
Technical Specs
- Maximum working water pressure: 1200kPa
- Maximum working water temperature: 60°C
- Hydrostatic test pressure: 2400kPa
- Lay length of 65mm Flanged device: 510mm
- Lay length of 80mm Flanged device: 510mm
- Lay length of 100mm Flanged device: 535mm
- Lay length of 100mm Grooved device: 500mm
- Lay length of 150mm Flanged device: 665mm
- Lay length of 150mm Grooved device: 620mm
Installation
Install device as per AS3500 and any local applicable codes and manufacturer’s instructions.
Applications
- For installation on fire service lines
- Protects against backflow caused by back siphonage and back pressure
- Maximum protection in Medium Hazard conditions in fire service systems
- Metered by-pass to detect low flow conditions and for unauthorised water use or leaks
Device Connections of 65mm, 80mm, 100mm and 150mm Double Detector Check Valve
Flow Characteristics of 65mm, 80mm, 100mm and 150mm Double Detector Check Valve