Single Testable Check and Single Detector Check
Product Code
- STCV100 – 100mm Single Testable Check Valve with Test Points (Flanged or Grooved)
- STCV150 – 150mm Single Testable Check Valve with Test Points (Flanged or Grooved)
- SDC100/WMBP – 100mm Single Detector Check Valve with 25mm Metered By-Pass (Flanged or Grooved)
- SDC150/WMBP – 150mm Single Detector Check Valve with 25mm Metered By-Pass (Flanged or Grooved)
- SDC100/WSBP – 100mm Single Detector Check Valve with 25mm Spacer By-Pass (Flanged or Grooved)
- SDC150/WSBP – 150mm Single Detector Check Valve with 25mm Spacer By-Pass (Flanged or Grooved)
Product Overview
MAGFLO™ Single Check and Single Detector Check Backflow Preventer delivers maximum protection in ‘Low Hazard’ conditions in fire service system and prevents against reversal of flow caused by back siphonage or back pressure to the potable water, with installation of the spacer or metered by-pass assembly for detecting low flow and unauthorised water use or leaks.
Features and Benefits
- Size options: 100mm and 150mm
- Flanged and Grooved connections
- Available with 20mm or 25mm metered or spacer by-pass
- Fusion bonded epoxy coated ductile iron construction
- Short lay lengths suitable for retrofitting to other brands
- Vertical or horizontal installations
- Top access entry for servicing
- Entire valve can be fully serviced inline – lightweight short lay length modular design
- Noryl™ replacement check valve
- WaterMark approved: AS/NZS 2845.1 WM-040347
- Lead Free
- 12-month limited warranty
Materials
- Valve Body – Ductile Iron
- Access Cover – Ductile Iron
- Polymers – Noryl™, NSF Listed
- Elastomers – Silicone
- Springs – Stainless Steel
- Coatings – FDA Approved Fusion Epoxy
Technical Specs
- Maximum working water pressure: 1200kPa
- Maximum working water temperature: 60°C
- Hydrostatic test pressure: 2400kPa
- Lay length of 100mm Flanged device: 430mm
- Lay length of 100mm Grooved device: 405mm
- Lay length of 150mm Flanged device: 505mm
- Lay length of 150mm Grooved device: 460mm
Installation
Install device as per AS3500 and any local applicable codes and manufacturer’s instructions.
Applications
- For installation on fire service lines
- Protects against backflow caused by back siphonage and back pressure
- Maximum protection in Low Hazard conditions in fire service systems
- Metered by-pass to detect low flow conditions and for unauthorised water use or leaks
Flow Characteristics of 100mm and 150mm Single Check and Single Detector Check Valve
Device Connections of 100mm and 150mm Single Check and Single Detector Check Valve
Note:
- Installation should comply to AS3500 - National Australian Plumbing Code and any other local and applicable codes
- Image is for illustration purposes only
- Due to continuous product improvement, changes to specifications may be made without prior notice